Distinct offers Network Monitor, the ONLY natural language Protocol Analyzer, ONC RPC for C++, .NET and Java, and IntelliTerm, the fastest Terminal Emulator for TN3270, TN5250 and VT420 on the market.

Distinct VIT: VT220: DataCapture

   Products   Downloads   Sales   Support   About us
  VIT
 



        
 

Summary

Use to start and stop data capture.

Syntax

Boolean DataCapture (CaptureFile, AppendFile)

CaptureFile String
AppendFile Boolean

Description

To capture all incoming data to a disk file or a specified file, call the DataCapture method. This action is only legal if the CaptureData or the CaptureDataFile property is True. Capturing incoming data to a disk file or a specified file is disabled by calling this method a second time. An application can check the value of the boolean InCaptureData or InCaptureDataFile property to determine if the VT220 ActiveX control is currently capturing incoming data to a disk file or a specified file, respectively.

The DataCapture method takes a capture file name (CaptureFile) and an append flag (AppendFile) as its parameters and returns a boolean. The CaptureFile parameter must be set to the file name to contain the incoming data. The append flag must be set to True to append to the file and false to overwrite. A VT_CAPTURE_DATA is invoked if the file string is empty. In this case, the append boolean is ignored. This action will display a dialog box to request for the name of the destination disk file from the user. If the file string is not an empty string, then VT_CAPTURE_DATA_FILE is invoked. In this case, the append boolean is looked at whether to append or overwrite the file if it already exists.

If incoming data can be successfully captured, then the method returns True; otherwise, it returns False. The application should ensure that the method was successfully executed by checking the return value.

Calling this method is equivalent to setting the VtAction property to VT_CAPTURE_DATA or VT_CAPTURE_DATA_FILE. This method can only be called after the VT220 emulation window has been created and initialized.

Example

Result = VT220Client.DataCapture ("test", TRUE)
If Result = False Then
MsgBox "Cannot capture incoming data to file", 64, "Sample Program"
End If



Browse FAQ

Related Products
Mail Objects

Recommended Add-On
Network Monitor,
Protocol Analyzer


Raves
"The night before I went on summer holiday we had to make some 'last minute' configuration changes to approx. 300 routers, a tedious job to do manually with telnet. We went along with MS Excel containing a list of IP-adresses to the routers, and the VIT telnet-component. One hour later the VBA-application (small is beautiful) was working, and after another hour all of our routers were updated with the new configuration. I just say a big "Thanks" to you all for a good sleep that night."
Eirik Brendholen, Ergo Integration AS

"We conducted a test session to compare the performance of similar products, and Distinct's product was better!" [more]
Dr. Shyam Sunder, Carnegie Mellon University

"Together with Distinct, we were able to offer our users an ideal soution to enabling them to connect to Yahoo! Pager, and to do so both quickly and reliably." [more]
Brian Park,
Producer of Yahoo! Pager, Yahoo! Inc.


  10/13/2008   Legal notices | PRIVACY Policy | Networking News |